NxT1 HSSI/V.35 ModuleUser ManualPart Number 1200771L161200771L1-1AMarch 2002
10Warranty and Customer ServiceADTRAN will replace or repair this product within five years from the date of shipment if it does not meet its publishe
11Customer Service, Product Support Information, and TrainingADTRAN will repair and return this product if within five years from the date of shipment
12Post-Sale SupportYour reseller should serve as the first point of contact for support. If additional support is needed, the ADTRAN Support web site
61200771L1-1 NxT1 HSSI/V.35 User Manual 13Table of ContentsList of Tables...
Table of Contents14 NxT1 HSSI/V.35 User Manual 61200771L1-1T1 Menus ...
61200771L1-1 NxT1 HSSI/V.35 User Manual 15List of TablesTable 2-1. T1 Pinout Connection ...
List of Tables16 NxT1 HSSI/V.35 User Manual 61200771L1-1
61200771L1-1 NxT1 HSSI/V.35 User Manual 17List of FiguresFigure 1-1. NxT1 HSSI/V.35 System ...
List of Figures18 NxT1 HSSI/V.35 User Manual 61200771L1-1
61200771L1-1 NxT1 HSSI/V.35 Module User Manual 19Chapter 1IntroductionNXT1 HSSI/V.35 MODULE OVERVIEWThe NxT1 HSSI/V.35 Module is a member of the ATLAS
901 Explorer BoulevardP.O. Box 140000Huntsville, AL 35814-4000(256) 963-8000© 2002 ADTRAN, Inc. All Rights Reserved.Printed in U.S.A.
Chapter 1. Introduction20 NxT1 HSSI/V.35 Module User Manual 61200771L1-1When combined with the supported ATLAS 800 Series base units and, optionally,
Chapter 1. Introduction61200771L1-1 NxT1 HSSI/V.35 Module User Manual 21TestsLine or payload loopback (Local and Remote)ConnectorsRJ-48CThe HSSI port
Chapter 1. Introduction22 NxT1 HSSI/V.35 Module User Manual 61200771L1-1PHYSICAL DESCRIPTIONThe NxT1 HSSI/V.35 Module (see Figure 1-2) plugs into any
61200771L1-1 NxT1 HSSI/V.35 User Manual 23Chapter 2InstallationBEFORE INSTALLING THE NXT1 HSSI/V.35 MODULECarefully unpack and inspect the NxT1 HSSI/V
Chapter 2. Installation24 NxT1 HSSI/V.35 User Manual 61200771L1-1INSTALLING THE NXT1 HSSI/V.35 MODULEFigure 2-1 represents the actions required to pr
Chapter 2. Installation61200771L1-1 NxT1 HSSI/V.35 User Manual 25WIRINGEach module T1 port uses a single RJ-48C jack to connect to a T1 circuit. Tabl
Chapter 2. Installation26 NxT1 HSSI/V.35 User Manual 61200771L1-1POWER UP AND INITIALIZATIONThe NxT1 HSSI/V.35 Module requires no initialization inpu
61200771L1-1 NxT1 HSSI/V.35 Module User Manual 27Chapter 3Operation OVERVIEWYou can control and configure the NxT1 HSSI/V.35 Module from a variety of
Chapter 3. Operation28 NxT1 HSSI/V.35 Module User Manual 61200771L1-1MODULESThe ATLAS 800 Series system controller automatically detects the presence
Chapter 3. Operation61200771L1-1 NxT1 HSSI/V.35 Module User Manual 29Table 3-1. Menu Tree for NxT1 HSSI/V.35 Modules MenuSLTRead security: 5Displays
3Safety InstructionsWhen using your telephone equipment, please follow these basic safety precautions to reduce the risk of fire, electrical shock, or
Chapter 3. Operation30 NxT1 HSSI/V.35 Module User Manual 61200771L1-1installing modules by simply specifying the module that you want to install in e
Chapter 3. Operation61200771L1-1 NxT1 HSSI/V.35 Module User Manual 31EMPTYThe system controller has not detected the presence of a module in the slot
Chapter 3. Operation32 NxT1 HSSI/V.35 Module User Manual 61200771L1-1NXT1 HSSI OPTION MODULEThe NxT1 HSSI/V.35 Module system controller automatically
Chapter 3. Operation61200771L1-1 NxT1 HSSI/V.35 Module User Manual 33T1 MENUSRead Security: 5Provides information about the four T1 interfaces locate
Chapter 3. Operation34 NxT1 HSSI/V.35 Module User Manual 61200771L1-1SESSeverely Errored Second (SES) is a second with 320 or more error events OR on
Chapter 3. Operation61200771L1-1 NxT1 HSSI/V.35 Module User Manual 35TX PRMControls the sending of performance report messaging (PRM) data on the fac
Chapter 3. Operation36 NxT1 HSSI/V.35 Module User Manual 61200771L1-1CONFIGRead Security: 5; Write Security: 5Contains parameters to include T1 data
Chapter 3. Operation61200771L1-1 NxT1 HSSI/V.35 Module User Manual 37Figure 3-4. HSSI Interface Loopback Test DiagramLA AND LB (Not applicable in V.
Chapter 3. Operation38 NxT1 HSSI/V.35 Module User Manual 61200771L1-1RX RATE AND TX RATEDisplays the current average receive and transmit data rate o
Chapter 3. Operation61200771L1-1 NxT1 HSSI/V.35 Module User Manual 39ATLAS FEATURES USED WITH NXT1 HSSI/V.35 MODULE OPTIONSTwo additional ATLAS 800 S
4Affidavit Requirements for Connection to Digital Services• An affidavit is required to be given to the telephone company whenever digital terminal eq
Chapter 3. Operation40 NxT1 HSSI/V.35 Module User Manual 61200771L1-1
61200771L1-1 NxT1 HSSI/V.35 User Manual 41Appendix ADedicated Maps ConfigurationThe DEDICATED MAPS menu assigns dedicated connections between any two
Appendix A. Dedicated Maps Configuration42 NxT1 HSSI/V.35 User Manual 61200771L1-1CURRENT MAPRead security:5Displays the name of the currently active
Appendix A. Dedicated Maps Configuration61200771L1-1 NxT1 HSSI/V.35 User Manual 43TO SLOTWrite security:3; Read security:5Specifies the slot to use f
Appendix A. Dedicated Maps Configuration44 NxT1 HSSI/V.35 User Manual 61200771L1-1NXT1 HSSI OPTION MODULECONNECTSWrite Security: 3; Read Security: 5E
Appendix A. Dedicated Maps Configuration61200771L1-1 NxT1 HSSI/V.35 User Manual 45SThis DS0 is used in the switched DIAL PLAN and conflicts with this
Appendix A. Dedicated Maps Configuration46 NxT1 HSSI/V.35 User Manual 61200771L1-1
61200771L1-1 NxT1 HSSI/V.35 User Manual 47IndexAAccessing the unit . . . . . . . . . . . . . . . . . . . . . . . . 27AlarmsOperation . . . . . . . .
IndexIndex-48 NxT1 HSSI/V.35 User Manual 61200771L1-1
5Affidavit for Connection of Customer Premises Equipment to 1.544 Mbps and/or Subrate Digital ServicesFor the work to be performed in the certified te
6I agree to provide ______________________ (telco’s name) with proper documentation to demonstrate compliance with the information as provided in the
7FCC regulations require that the following information be provided in this manual:1. This equipment complies with Part 68 of FCC rules. On the back o
8Federal Communications Commission Radio Frequency Interference StatementThis equipment has been tested and found to comply with the limits for a Clas
9Industry Canada Compliance InformationNotice: The Industry Canada label applied to the product (identified by the Industry Canada logo or the “IC:” i
Kommentare zu diesen Handbüchern