Application Views Adtran TSU IQ Configuration Application (AdTSUIQConApp)
Device Management Page 68 Adtran DSU/CSU
Sampling Rate
Allows you to set the sampling rate for frame relay
monitoring. Options are min5, min10, min15,
min20, and min30.
Maximum PVC supported
Sets the maximum PVCs supported by the IQ unit
(Range 1 - 100).
DTE Port Configuration View
Access: From the Icon Subviews menu for the
AdTSUIQConApp, select DTE Port Configuration.
This view displays the following information.
Physical Layer Configuration
CTS Option
Selects the Clear to Send (CTS) option. Options
are forcedOn and followRTS
CD Option
Selects the Carrier Detect (CD) option. Either
normal or forcedOn.
DSR Option
Selects the Data Set Ready (DSR) option. Either
normal or forcedOn.
Transmit Clock Phase
Sets the phase of the DTE Transmit clock. Either
normal or inverted.
Flow Control
Determines how the IQ device will respond to
congestion during DBU operation. If set for none,
the IQ will drop frames during DBU operation
when severe congestion occurs. If set for
hardware, the IQ will vary the DTE TC clock in
order to control the amount of data offered to the
IQ when severe congestion occurs. fECNBECN
mode will set the FECN bit in outbound frames
and set BECN bit for inbound frames leaving flow
control up to the DTE devices.
Frame Relay Layer Configuration
Port Management DLCI
Selects the DTE Port Management DLCI (Range
16 - 1007).
Management PVC
Controls the presence of the DTE management
PVC in a full status response to the DTE device.
Either enabled or disabled.
Timeout, T392
Sets the timeout in seconds between polling
intervals (Range 5 - 30).
Error Events, N392
Sets the number of error events for the frame
relay management (Range 1 - 10).