7. SPECIFICATIONS
Specifications for the Dual LIU are detailed in Table 4.
8. WARRANTY AND CUSTOMER SERVICE
ADTRAN will replace or repair this product within the
warranty period if it does not meet its published specifi-
cations or fails while in service. Warranty information
can be found at www.adtran.com/warranty
.
Refer to the following subsections for sales, support,
Customer and Product Service (CAPS) requests, or
further information.
ADTRAN Sales
Pricing/Availability:
800-827-0807
ADTRAN Technical Support
Pre-Sales Applications/Post-Sales Technical
Assistance:
800-726-8663
Standard hours: Monday - Friday, 7 a.m. - 7 p.m. CST
Emergency hours: 7 days/week, 24 hours/day
ADTRAN Repair/CAPS
Return for Repair/Upgrade:
(256) 963-8722
Repair and Return Address
Contact CAPS prior to returning equipment to
ADTRAN.
ADTRAN, Inc.
CAPS Department
901 Explorer Boulevard
Huntsville, Alabama 35806-2807
Table 4. Dual LIU Specifications
Specification Description
Environmental
Operating Temperature:
Storage Temperature:
Relative Humidity:
Maximum Current Draw
@ –48 VDC:
Maximum Heat
Dissipation:
–40°C to +65°C
–40°C to +85°C
95 percent maximum @
50°C, noncondensing
Online: 0.042 amps
Offline: 0.025 amps
Online: 2.02 watts
Offline: 1.21 watts
Physical
Dimensions:
Weight:
Height: 3.125 inches
Width: 1.14 inches
Depth: 10.1 inches
0.9 pounds
Part Number
Total Access 1500
Dual LIU: 1180009L1