Chapter 1. Introduction
61200264L1 Quad E1/PRA Module User Manual
1-3
Specifications
Each port of the Quad E1/PRA Module conforms to the following specifica-
tions:
PHYSICAL DESCRIPTION
The Quad E1/PRA Module plugs into any available option slot in the rear of
the ATLAS 800 or ATLAS 800
PLUS
(see Figure 1-2).
Figure 1-2. Quad E1/PRA Module
Line rate
2.048 Mbps, +
75 bps
Capacity
E1: 1 to 31 TS0s
PRA: 30B +D
Line Codes
HDB3, AMI
Framing
NFAS, FAS, TS16 MF and CRC-4
Tests
Self test, line loopback, port loopback
Connectors
DB-15 (using supplied converter cable)
Terminating Impedance
120 ohms balanced + 5%
75 ohms unbalanced +
5% (with P/N 1200209L1)
75 ohms balanced +
5% (with P/N 1200209L1)
QUAD E1-PRA
Kommentare zu diesen Handbüchern