ADTRAN T1/PRI Bedienungsanleitung Seite 32

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 52
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 31
Chapter 3. Operation
3-10 Dual T1/PRI Module User Manual 61200314L1-1
QRSS/RLB
R
ESULTS
Write security: 4; Read security: 5
Displays current status of T1 tests including information regarding loop-
backs and test patterns. When displaying tests pattern status, the display
string is composed of pattern sync status, and errored seconds.
CLR Write security: 3; Read security: 5
Clears error counters on test pattern results menu.
INJ Write security: 3; Read security: 5
Injects errors into transmitted test pattern.
ATLAS 550 FEATURES USED WITH DUAL T1/PRI MODULE
In addition tothe Dual T1/PRI Module menuitems, twoadditional ATLAS
550 menu items may be operatedin conjunction withthe DualT1/PRI Mod-
ule. These are F
ACTORY
R
ESTORE
and R
UN
S
ELF
T
EST
.
F
ACTORY
R
ESTORE
F
ACTORY
R
ESTORE
restores the factory-installed default setting for all Dual
T1/PRI Module parameters. When “Factory Restore” displays, place the
cursor on it andpress
Enter
. The unit is restored to preset factory defaults
and returns to the main ATLAS 550 menu.
R
UN
S
ELF
T
EST
R
UN
S
ELF
T
EST
, a submenu of the ATLAS 550 main menu item T
EST
,exe-
cutestheATLAS550internaltestfortheDualT1/PRIModule.Foraddition-
al information on S
ELF
T
EST
see the ATLAS 550 User Manual.
None No sync.
LOS Sync has been lost.
Sync Pattern is synchronized.
ES Number of seconds with at least one bit error.
Seitenansicht 31