ADTRAN T200 FNID Spezifikationen Seite 2

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 76
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 1
2 61184002L3-5B
SONET OC-3LR-1 optical interface
Rate: 155.52 Mb/s
Span length: Long Reach, 40 km
Wavelength: 1310nm (nominal)
NOTE
The OPTI-3 is an LR (long reach) optical product.
When interfacing with IR (intermediate reach)
3rd party equipment, the optical receive signal
may need to be padded to avoid overloading the
optical receive signal. The receive signal level
should be within 8 dbm to 28 dbm for IR
equipment.
Dual SC optical connections
Framing, multiplexing and mapping compliant
with SONET standards
OC-3 facility and equipment loopback
Detects and indicates standard optical and
SONET related alarms and conditions
SONET level performance monitoring
SONET line protection switching
1+1 equipment and facility protection for optical
network interface
1:1 equipment protection for optical network
interface
Maximum 60ms protection switching time (OC-3
to low speed interface)
Board-mounted manual APS control switch
Provide three Clear Channel DS3 Signals (via
BNC connectors)
Two external DS1 BITS clock interfaces
Three sense points including AUX1, AUX2, and
AUX3
Fully hot swappable
External BITS, line, or free-run timing modes
SONET Minimum Clock (SMC) with +/– 20
ppm accuracy
OAM&P via data communication over Section
DCC channel
Support SONET section DCC bridging
Support for OSI/IP Tunnelling
Controller cards Cross Copy Communication
Link
OAM&P interface via craft interface (DB-9)
TL1, Telnet, SNMP, and TFTP over Ethernet
Supports Software downloads locally via craft
interface (DB-9) and TFTP over Ethernet or OSI
Tunnel.
TL1 management support
Supports TL1-based GUI network management
interface
Provides 3 DS3 interfaces
Software-controlled DS3 Transmit Level Control
Automatic Receive Equalization
Software-controlled Remote and Local DS3
Loopback capability
Monitors incoming Receive Signal for LOS
(Loss Of Signal)
Monitors the Receive Analog and Digital LOS
Monitors Transmit Output signal for drive failure
LED status indicators:
Board Status (Power/Fail)
Optic Status (LOL, LOF, etc.)
DS3 #1 Status
DS3 #2 Status
DS3 #3 Status
ACO
External ACO input (RMC only)
Figure 2. OPTI-3 Rackmount Chassis
Figure 3. OPTI-3 Wallmount Chassis