Ethernet Traffic Generation & Monitoring Test
Multi Protocol Test Set 169
Throughput Results
Note: When the Throughput Pass/fail verdict is selected as the Current RX Rate,
the Pass/Fail Verdict is declared as Fail as soon as the test-stream current
receive rate is over the maximum threshold or below the minimum
threshold.
Note: When the Throughput Pass/fail verdict is selected as the Average RX Rate,
the Pass/Fail Verdict is declared as Fail as soon as the test-stream average
receive rate is over the maximum threshold or below the minimum
threshold. The Pass/Fail Verdict is evaluated every second and the final
Pass/Fail Verdict correspond to the verdict at the last second of the test. See
Throughput Pass/Fail Verdict on 135.