C A U T I O N
C A U T I O N
!
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
For more information, refer to the applicable Installation and Maintenance Practice
(P/N 61179641L4-5 or 61179641L6-5) available online at www.adtran.com
.
Warranty: ADTRAN will replace or repair this product within the warranty period if it does not
meet its published specifications or fails while in service. Warranty information can
be found online at www.adtran.com/warranty
.
©2009 ADTRAN, Inc. All Rights Reserved.
PRICING AND AVAILABILITY 800.827.0807
TECHNICAL SUPPORT 800.726.8663
RETURN FOR REPAIR 256.963.8722
*61179641L4-22A*
NOTE
Access to the Total Access 1200 Series units is now
available through the Total Access 1200F craft access or
Inband Management access ports.
MAINTENANCE
The Total Access 1248 does not require routine hardware
maintenance for normal operation. Do not attempt repairs in
the field. Repair services may be obtained by returning the
defective unit to ADTRAN. Refer to the warranty for further
information. Field support for software is provided through
upgrade facilities.
Fan Modules
Four fans are installed in the Total Access 1248 in a removable
module to maintain the hardware within proper operating
temperature tolerances. With the exception of the filter, the fan
module is not field serviceable. The fan module (P/N
1179675G1) is field replaceable and is available from
ADTRAN.
To remove a fan module, perform the following steps:
1. Loosen the screw that holds the fan module in place.
2. Remove the fan module by pulling it straight out of the
chassis.
To install a new fan module, perform the following steps:
1. Insert the new fan module by pushing it straight into
the chassis.
2. Tighten the screw that holds the fan module in place.
Fan Filters
The Total Access 1248 fan module comes with a single fan
filter. The filter is designed to remove particles from the air
before it is pushed through the system.
Replacement filters are available from ADTRAN individually
(P/N 1179676G1) and in quantities of 20 (P/N 1179676G2).
The filter should be inspected at least every 90 days and
replaced as necessary.
To replace a filter, remove the fan module, remove the old filter
material and tuck the new filter in, ensuring that the edges of
the filter are behind the metal tabs provided to hold the filter.
COMPLIANCE
The Total Access 1248 is NRTL listed to the applicable UL
standards. The Total Access 1248 meets or exceeds all appli-
cable requirements of NEBS, Telcordia GR-63-CORE, issue 3,
and GR-1089-CORE, issue 4. The Total Access 1248 is
intended for deployment in EEC’s, in Pedestals, directly in the
OSP, and in locations where the NEC applies. Install the Total
Access 1248 in a restricted access location.
This device complies with Part 15 of the FCC rules. Operation
is subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received,
including interference that may cause undesired
operation.
Changes or modifications not expressly approved by ADTRAN
could void the user’s authority to operate this equipment.
Electrostatic Discharge (ESD) can damage electronic
modules. When handling modules, wear an antistatic
discharge wrist strap to prevent damage to electronic
components. Place modules in antistatic packing
material when transporting or storing. When working on
modules, always place them on an approved antistatic
mat that is electrically grounded.
Per GR-1089-CORE, Section 9, the Total Access 1248 is
designed to be deployed in DC-C (common) configuration
or DC-I (isolated) installation.
Per GR-1089-CORE the Total Access 1248 is designed
and intended for installation as part of a Common
Bonding Network (CBN). The Total Access 1248 is not
designed nor intended for installation as part of an
Isolated Bonding Network (IBN).
The Total Access 1248 frame ground terminal must be
connected to a reliable earth ground.
Connect to a reliably grounded –48 VDC source which is
electrically isolated from the AC source. The branch
circuit overcurrent protection shall be a fuse or circuit
breaker rated minimum –48 VDC, Maximum 3A.
NOTE
The POTS and ADSL+POTS ports are classified as Type 1, 3,
and 5 as defined in Appendix B of GR-1089-CORE, Issue
4 and meet the lightning and power fault criteria with
any primary protector that meets any of the voltage
limits of GR-974-CORE or GR-1361-CORE (i.e., carbon
blocks, gas tubes, solid states, etc.). Solid-state primary
protectors are not recommended as they could affect the
signal integrity of the ADSL.
Current limiting protectors are not required.
Configuration Code Input Output
Power Code (PC) F C
Telecommunication Code (TC) X X
Installation Code (IC) A