2 Section 61150043L1-5, Issue 3 61150043L1-5C
All models include tamper-resistant features,
replaceable surge arrestor Gas Tubes, externally
accessible order wire terminals, lockable clamp, 6
AWG ground cable, 40-foot cable stubs, mounting
bracket, quick-reference housing wiring labels, and
detailed connection information for the various
circuit technologies. The housing is available with
air-core or gel-filled cable, depending on the model.
A Test Access Card is shipped with each Housing to
assist with installing and troubleshooting T400 and
T200 circuits. Refer to the Test Access Card I/M
Practice (61244065L1-5) for more details.
Revision History
This practice has been revised to include a one-page
circuit technology wiring chart, update the
replacement parts list, reflect a change in the gas
tube insertion/extract tool, and update the Warranty
and Customer Service section information.
2. INSTALLATION
CAUTION
Never install telephone wiring during a
lightning storm.
After unpacking the unit, immediately inspect it for
possible shipping damage. If damage is discovered,
file a claim immediately with the carrier, then
contact ADTRAN Customer Service.
The Repeater Housing consists of a mounting
bracket, a base, a circuit pack support structure, a
support case cover, a clamp, an O-ring, and a dome.
The mounting bracket is shipped attached to the
Repeater Housing. A stainless steel locking clamp
secures the bottom of the dome to the base of the
housing using an O-ring to form an air-tight seal. A
tamper-resistant screw with a captured cup washer
is provided to attach to the clamp for additional
security. Figure 2 shows the parts of the housing.
Figure 2. Repeater Housing Assembly
Dome
Bracket
Circuit Pack
Support
Structure
Support
Case
Cover
Clamp
Base
O-ring
Ground Cable
Attach to
Earth Ground
WARNING
RELEASE PRESSURE
BEFORE OPENING CLAMP
PRESSURIZE TO
9 P.S.I.G.
T-bar
Warning Tag
Padlock Hasp
T-bolt
Catch
Seitenansicht 1