4 Section 61150043L1-5, Issue 3 61150043L1-5C
Follow these steps to install the housing.
A. Install Mounting Bracket
NOTE
The Repeater Housing is designed to be mounted
vertically, with the cable stub down.
(1) Clearances between the Repeater Housing
and adjacent structures must be observed for
access during maintenance. Refer to Figure
4 for the clearances required for removing
the housing cover and the tilting internal
case support.
(2) Verify that the proposed cable route does not
exceed the 40-foot stub cable length.
(3) The mounting bracket contains holes for
mounting the unit to a pole, in a vault, or in
a manhole. A guide for mounting bracket
holes is illustrated in Figure 5. Select the
location for mounting the unit and fasten the
mounting bracket appropriately.
B. Splice Wires
(1) Connect the wiring in the cable stub based
on the appropriate matching repeater
technology and housing wiring. Refer to
Table A for deployment restrictions, and to
Table B for circuit technology wiring
information.
Figure 5. Guide for Mounting Bracket Holes
6.0"
1.0" 2.0" 2.0"
6.0"
3.0"
4.0"
1.25"
0.675"Typical
(9 places)
Figure 4. Mounting Clearances
21"
15"
12"
24"
36"
ADTRAN
Circuit Quantity per
Technology Mechanical Size Housing
HDSL HRE ............... T400 or T200
1
....... 4
HDSL HTU-R ........... T400 or T200
1
....... 2
HDSL FNID .............. T400 or T200
1
....... 3
ISDN TRI-R .............. T200 ............................ 4
ISDN BRIDLE-R ...... T400 ............................ 4
Table A.
Repeater Housing Capacity Specifications
1
Capacity verification pending Thermal Load tests
NOTE
Some slot pairs inside the housing may not be
used, depending on the specific circuit
technology wiring.
(2) If installing an air-pressurized model (List 1)
and using remote pressurization, an air-tight
splice enclosure must be installed.
(3) Connect the ground cable to an appropriate
ground. Surge arrestors work only when the
ground cable is connected.
Seitenansicht 3