MX2800 STS-1 User Manual Statistics, Section 5
Protection Switch Statistics
61204659L1-1A 5-13
4. PROTECTION SWITCH STATISTICS
This menu provides statistics regarding protection switches. The number of protection switches that occur
within the particular time period will be listed. (See Figure 5-14)
Figure 5-14. Protection Switch Statistics Menu
Performance Parameters
View performance parameter information for protection switch counts in one of the three time period
selections. Information in these fields is for the given time period since the last reset. When viewing the
24-hour history statistics, use the left and right arrow keys to scroll through all 96 15-minute intervals.
Clearing protection switch alarm counts will clear the Excessive Switch State if active.
5. ALARM LOG
This menu provides a list of the last 200 alarms that have occurred on the MX2800. When the alarm log
becomes full, new alarms replace the oldest alarms in a first-in, first-out sequence.
The alarm log is periodically stored in nonvolatile memory. Once every minute, if an alarm has been
recorded or if the alarm log has been reset since the last time it was saved, the alarm log and system
configuration are saved to nonvolatile memory. When executed, both the alarm log and system configura-
tion are saved manually by the Save Configuration & Alarm Log function (refer to Save Configuration and
Alarm Log on page 3-43). Each time the system powers up, the alarm log is retrieved from non-volatile
memory.
A Reset Alarm Log function is accessible from the alarm log menu. This option clears the alarm log. See
Figure 5-15.