4 61181409L10-5B
4. MENU STRUCTURE
The following subsections describe the Quad T1/E1
IMA Module menus. Figure 2 provides a menu tree
for the IMA Module.
Main Menu
The Main Menu allows the user to access the module
for various functions such as Configuration,
Provisioning, Status, Test, and Performance
Monitoring.
Configuration Screen
The Configuration Screen is a read-only display. It
displays configuration data pertaining to the module
and cannot be changed. Information such as software
revision will change and will be reflected as the
software upgrades are performed.
Figure 2. Quad T1/E1 IMA Access Module Menu Tree
Octal DS1/E1 IMA
Access Module
1. Configuration
Unit Name
CLEI Code
Part Number
Serial Number
Product Revision
Software Revision
Boot Revision
2. Provisioning
3. Out of Service - Unassigned
2. Out of Service - Maintenance
1. In Service
2. Version 1.1
1. Version 1.0
2. FAS + CRC
1. FAS
2. Secondary DS1/E1 Timing Source
1. Primary DS1/E1 Timing Source
2. D4
1. ESF
2. Enable
1. Disable
2. Enable
1. Disable
2. Enable
1. Disable
2. Enable
1. Disable
2. Qtr Hour
1. Daily
1. IMA Group 1
5. Unassigned
3. IMA Group 3
2. IMA Group 2
4. IMA Group 4
1. IMA Group 1
5. Unassigned
3. IMA Group 3
2. IMA Group 2
4. IMA Group 4
2. Line Code
1. Framing Format
4. IMA Group Number
3. Payload Scrambling
2. TFTP
1. Ymodem
2. AMI
1. B8ZS
2. AMI
1. HDB3
3. Status
4. Test
2. Transmit Identification
3. Transmit Frame Length
1. Group Admin State
5. Performance Monitoring
* NOTE: Either "Y modem" or "TFTP" will replace "Type," depending on selected protocol.
2. File Name
3. Start Type* Download
1. Selected Protocol
4. Abort Transfer
2. DS1/E1 Port Tests
3. Clear All Loopbacks
1. IMA Group Tests
2. 64
3. 128
4. 256
1. 32
5. Max IMA Link Delay
6. IMA Version
4. Min Active IMA Links
2. 133-266 ft DSX-1
3. 266-399 ft DSX-1
1. 0-133 ft DSX-1
5. 533-655 ft DSX-1
1. 0 dB CSU
4. 399-533 ft DSX-1
2. -7.5 dB CSU
4. -22.5 dB CSU
3. -15 dB CSU
2. Line Code
3. Line Build Out
1. Framing Format
5. IMA Group Number
4. Payload Scrambling
2. DS1/E1 Ports
(If DS1)
(If E1)
5. IMA Timing Source
1. IMA Group
2. E1
1. DS1
3. Port Mode
2. Long Haul
1. Short Haul
4. Line Build Out Mode
2. ATM Loopback Toward DS3 ATM CSM
1. ATM Loopback Toward IMA
7. Download New Software
6. Restore Factory Defaults
2. Line Loopback
3. Local Loopback
1. Payload Loopback
2. DS1/E1 Performance Monitoring
3. IMA Group Performance Monitoring
4. Reset Performance Monitoring
1. IMA Link Performance Monitoring
(If Long Haul)
(If Short Haul)