Chapter 3. Operation
61202129L1-1 TSU 120 User Manual 3-11
T-WATCH Pro/EIA-232 Connection
To set up the TSU 120e to work with T-WATCH Pro over a
direct EIA-232 connection, follow these steps:
SNMP
The ADTRAN TSU 120 supports the Simple Network Manage-
ment Protocol (SNMP) through the chain-in (SLIP) interface.
The TSU 120e offers a 10BaseT connection which also supports
SNMP. For more information on SNMP see Appendix A, Under-
standing SNMP on page A-1.
To use SNMP via 10BaseT (TSU 120e only), follow these steps:
Step Action
1 Set the Unit ID and set a passcode using the front
panel. See Unit ID on page page 6-4 and Set a Passcode
on page 6-4 for details.
2 Set the control port rate to the same setting as the PC
Com port.
3 Connect the PC Com port to the chain-in port on the
TSU 120 using the DB25 adapter and modular cable
provided.
4 Follow the installation instructions for T-WATCH Pro
to start the program and to connect to the unit.
Step Action
1 Set C
ONTROL
P
ORT
to
N
ORMAL
.
2 Set the IP
ADDRESS
,
DEFAULT
GATEWAY
, and
SUBNET
MASK
.
3 The appropriate MIB browser must be loaded into the
Network Management Station (available on the
ADTRAN webpage at http://www.adtran.com).
4 The MIB browser issues SNMP gets/sets to the TSU
120e.