Chapter 10. Dial Backup Configuration
61200208L1-1 Express 5210 User Manual 10-3
DBU Options
Beeper Option
If enabled, the Express 5210 issues an intermittent beep while in
dial backup.
Password Opt
When enabled, the passwords entered in the
DBU P
ASSWORD
fields
of both the near and far end Express 5210s are required to match
before a dial backup connection can be made. The setting in this
field must also be identical in both units (i.e., they both must be set
to either
E
NABLED
or
D
ISABLED
). This selection does not apply
when the 4-Wire SW56 card or DCE card is installed.
DBU Password
Enter the authentication string used for making a dial backup
connection. If
P
ASSWORD
O
PT
is
E
NABLED
, the near and far end
Express 5210
DBU P
ASSWORDS
must be identical. If using front
panel entry, see the section Entering Letters Using the Front Panel on
page 11-4 for more information. This selection does not apply
when the 4-Wire SW56 or DCE card is installed.
Daily Lockout
Enable/disable the daily lockout specified by the fields
L
OCKOUT
S
TART
and
L
OCKOUT
E
ND
.
Lockout Start
Enter the hour that the
D
AILY
L
OCKOUT
begins and dial backup is
disabled (0 to 23). Only applies if the
D
AILY
L
OCKOUT
parameter is
set to
E
NABLE
.
Lockout End
Enter the hour that the
D
AILY
L
OCKOUT
ends and dial backup is
reactivated (0 to 23). Only applies if the
D
AILY
L
OCKOUT
parameter
is set to
E
NABLE
.
Weekend Lock
If enabled, no backup will occur from midnight Friday to midnight
Sunday.