ADTRAN MX410 Spezifikationen Seite 54

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 134
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 53
MX410/MX412 System Manual
4-12 61189500L1-1F
–48 VDC systems: –42 VDC to –60 VDC
–24 VDC systems: –22 VDC to –27 VDC
+24 VDC systems: +22 VDC to +27 VDC
Place the common (normally black) lead of the voltmeter on the RET A post of the DC
power terminal block and the DC volts (normally red) lead on the
PWR A post of the DC
power terminal block.
c. Repeat step 3 for the RET B/PWR B connections.
4. Install at least one PSU into the MX410 front panel
PSU A or PSU B slot.
a. Line up the PSU with the guide grooves and carefully insert the unit into the MX410
until it seats all the way into the PSU slot of the MX410.
b. Tighten the thumb screws to secure the PSU in place.
To remove a PSU, remove the thumb screws that hold the PSU in place and carefully pull the
PSU straight out of the MX410.
Refer to “LED Indicatorson page 4-10 for LED indication of successful power turn-up.