ADTRAN 600R Spezifikationen Seite 146

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 196
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 145
146 © 2002 ADTRAN, Inc. 61200600L1-1A
Section 5 DLP-006 Total Access 600R System Manual
DLP-006
1. Connect the computer to the unit’s CRAFT port as shown in DLP-001, Connecting the Terminal or PC
to the CRAFT Port.
2. Log in to the unit as shown in DLP-002, Logging in to the System.
3. Select S
YSTEM CONFIG, MANAGEMENT, and TELNET ACCESS.
4. Right arrow to A
UTHEN METHOD and press <Enter>. Select PASSWORD, RADIUS, PASSWORD/RADIUS, or
R
ADIUS/PASSWORD and press <Enter>.
5. Verify the T
ELNET ACCESS is set to ON. Down arrow to select USER LIST and press <Enter>.
The following screen will appear.
6. Use the right arrow key to select the NAME field; press <Enter>. Enter a username to be used for
Telnet logins.
7. If P
ASSWORD was selected for the AUTHEN METHOD in Step 4, right arrow over to PASSWORD; press
<Enter>. Enter a password to be used for Telnet logins.
8. Use the right arrow key to select I
DLE TIME (MINS); press <Enter>. This field defines the amount of time
in minutes the Telnet session may be idle before the user is logged off. The range is 1-255. The
default value is 10 minutes. Enter the appropriate I
DLE TIME.
9. Use the right arrow key to select L
EVEL. Select the appropriate security level. For security level
definitions, reference DLP-003 Adding/Removing Telnet Users and Changing Password Security
Levels.
10. This completes the addition of one Telnet user. Repeat Steps 1-9 for each user needing Telnet
access.