Appendix C. Frame Relay Examples
61200305L1-1 ATLAS 550 User Manual C-9
Step 1 From P
ACKET
M
ANAGER
/P
ACKET
E
NDPNTS
/C
ONFIG
, create the packet end-
points:createaframerelayendpointfortheprivateframerelaylink,and
createa TBOP linktocarry the signalingbetween the PBXs(seeFigure C-25).
Figure C-25. Menu for Creating Packet Endpoints
Step 2 From P
ACKET
M
ANAGER
/P
ACKET
E
NDPOINTS
/C
ONFIG
/S
UBLINKS
,configure
the sublinks.
All 23 voice channels can be carried by one DLCI transported on five DS0
channels. One DS0 and one DLCI are required for the TBOP channel carry-
ing the signaling between the PBXs. To ensure that both the voice and the
TBOP DLCIs are allocated their necessary frame relay bandwidth, set the
Quality-Of-Service (QOS) parameter with 64K allocated to the TBOP chan-
nel and 320K (5*64) allocated to the voice channels (seeFigure C-26).
Figure C-26. Menu for Configuring Sublinks
Step 3 Connect the TBOP packet endpoints. Connect the TBOP data path between
the DS0 containing the signaling information and the private frame relay re-
source (see Figure C-27).
Figure C-27. Menu for Connecting the TBOP Endpoints
Step 4 Connectpacketendpointstothephysicallinks.EachDS0carryingvoice from
the PBX must be connected to the frame relay endpoint (see Figure C-28).