Chapter 9. Dedicated Circuit Backup and Circuit Status
9-6 ATLAS 800
PLUS
User Manual 61200226L1-1
>
BKUP STATUS
(BACKUP
STATUS)
String indicates the current status of the dedicated line. The following selec-
tions are available for the
Backup Status
menu item.
>
LINE STATUS
This gives you the overall status of the connection. The following selections
are available for the
Line Status
menu item.
>
DELAY
When present, this indicates that one ATLAS has detected a change in state
and is counting down to delay/restoral.
FB
Backup is forced through the interface menu.
FR
Restoral is forced through the interface menu.
Primary
The link is active.
Dialing
Attempting to dial the backup link.
Exceeded Max Num Redials.
Will retry backup dial in [num] seconds.
The link is in error and waiting on backup.
Backup Failed
Retry Dial
[num]
Primary Down
Answering
The link is answering a backup endpoint.
The link is in backup.
Backup
Unknown
Endpoints do not support (or are not configured) for moni-
toring.
Active
The connection is up and running.
Inactive
The connection is down due to configuration (i.e., the DTR
is down).
Data Alarm
The FROM endpoint is in data alarm.
The TO endpoint is in network alarm.
Both the FROM endpoint and the TO endpoint are in alarm.
The status of the FROM endpoint is unknown.
Network
Alarm
Net/Data
Alarm
Data
Unknown