Chapter 7. Configuring the DCE Port
61200214L1-20 IQ Probe User Manual 7-5
Maximum PVC Count (MAX PVC COUNT)
Sets the maximum number of PVCs that the IQ Probe will monitor for sta-
tistical information. This value determines the amount of history intervals
available for storage. To get the maximum amount of statistical history
storage, set this value equal to the number of PVCs assigned to the frame
relay port. A smaller value increases history interval count but puts some
of the PVC statistics into the unknown category.
History Interval Count (HIST INT COUNT)
Sets the number of history intervals to store for statistics. History intervals
are displayed in the V
IEW
BY
I
NTERVAL
portions of the S
TATISTICS
menus.
These views provide data divided into columns grouped by the interval of
time selected in the H
ISTORY
I
NTERVAL
S
IZE
field (see History Interval Size
(HIS INT SIZE) on page 9-6 for more information). The H
ISTORY
I
NTERVAL
C
OUNT
field determines how many intervals can be stored at a time. The
maximum value allowed is affected by the previously mentioned PVC
Count selection.
PVC Options (PVC CONFIG)
The PVC Options table enables optional features such as delay measure-
ment for each PVC. DLCI numbers and their corresponding committed in-
formation rates (CIRs) are supplied by the service provider.
When configuring PVC options using the front panel, the
Next
,
Prev
,
Add
, and
Delete
keys are used. See Operation on page 3-1
for more information on front panel operation.