61189500L1-1F 2-1
Section 2
Engineering Guidelines
GENERAL
This section provides engineering guidelines for network designers who are incorporating an
MX410/MX412 into their network.
COMPLIANCE
The MX410/MX412 complies with the requirements covered under UL 60950 and NEBS Level
3. The MX410/MX412 is intended to be installed in a restricted access area only.
The MX410/MX412 complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions:
1. The device may not cause harmful interference.
2. The device must accept any interference received, including interference that may cause
undesired operation.
Changes and modifications not expressly approved by ADTRAN could void the user’s authority
to operate this equipment.
WARNING
The V.35, Ethernet, terminal server, craft port, and FXS port (if
present) interfaces are not to be connected to outside plant (OSP)
facilities.
CAUTION
Per GR-1089-CORE October 2002, Section 9, this system is
designed and intended only for installation in a DC-C (common)
Bonding and Grounding system. It is not intended or designed for
installation in a DC-I (isolated) Bonding and Grounding system.
The ground wire must be of equal or greater ampacity than the wire
connected to the VDC return.
The Configuration Codes for the MX410/MX412 and the MX410 PSU are provided in Table 2-
1 and Table 2-2.