Section 5 DLP-4 Total Access 544R System Manual
110 © 2003 ADTRAN, Inc. 61200704L2-1B
1. Connect the unit to your VT100 system (details found in DLP-1, Connecting the Terminal or PC to the
CRAFT Port).
2. Log in to the system with maximum rights (details for logging in are in DLP-2 and
DLP-3).
3. From the R
OUTER/CONFIG/INTERFACES (ETH) menu, select the SETUP option and press <Enter>.
4. Select the P
RIMARY IP option and press <Enter>. Select IP ADDRESS and press <Enter>.
Enter the appropriate IP address.
5. From the ROUTER/CONFIG/INTERFACES (ETH)/SETUP/PRIMARY IP menu, select the SUBNET MASK option
and press <Enter>.
Enter the appropriate Subnet Mask.
6. From the ROUTER/CONFIG/ROUTES menu, select the DEFAULT GATEWAY option and press <Enter>.
Enter the appropriate Default Gateway.
7. Escape out to the ROUTER menu and log off by pressing <Ctrl + L>.
Follow-up Procedures
Once this procedure is complete, return to the procedure which referred you to this DLP and continue with
the tasks indicated there.