Section 5 DLP-11 Total Access 544R System Manual
134 © 2003 ADTRAN, Inc. 61200704L2-1B
Perform Steps Below in the Order Listed
1. Connect to the unit using the RJ-45 CRAFT interface.
If you are not already connected to the unit’s CRAFT interface (either with a VT100 compatible
terminal or with a PC running VT100 emulation software), follow the procedure in DLP-1, Connecting
the Terminal or PC to the CRAFT Port. Connecting to the
CRAFT port interface limits the config
transfer procedure to XMODEM only.
2. Log in to the unit. (See DLP-2, Logging in to the System, for details.)
3. Go to the S
YSTEM UTILITY menu and select CONFIG TRANSFER menu; press <Enter>.
4. Set the T
RANSFER METHOD menu to XMODEM.
5. Select S
AVE CONFIG REMOTELY to start the transfers. Enter Y to confirm the transfer and prepare the
unit for the transfer download. The following message is displayed: “This will begin sending a copy
of the current system configuration.”
When the unit is ready to send the configuration file, “XMODEM/CRC: Receive CONFIG file
now...” is displayed in the bottom left corner of the terminal window. While this message is visible the
menus are not available.
6. Configure the VT100 terminal or terminal emulation software to RECEIVE (you are prompted for
filename).
7. From the terminal evaluation software, begin the XMODEM transfer by using the appropriate
command sequence. For Windows HyperTerminal, select T
RANSFER > RECEIVE FILE. Enter the
filename (including path) and select XMODEM as the T
RANSFER METHOD.
If necessary, refer to the terminal emulation software documentation for help. Also, when specifying
the filename, ensure that the filed save a .cfg extension. Otherwise, the file may not be available for
uploading into the other units.
Because XMODEM data is being transferred in-band through the menu interface, the VT100 menus of
the unit will be inoperable from the
CRAFT interface. You can cancel the update at any time within the
terminal emulation software. (Please consult the documentation provided by the terminal emulation
software to determine how to do this).
8. When the transfer has successfully completed, IDLE displays in the CURRENT TRANSFER STATUS field
and U
PLOAD COMPLETE displays in the PREVIOUS TRANSFER STATUS field.
Follow-up Procedure
Once this procedure is complete, return to the procedure which referred you to this DLP and continue with
the tasks indicated there.