Appendix A. Acceptance Test Procedure
A-14 MX2810 M13 User Manual 61185001L1-1
2. From the System Management Configuration screen, select Local IP
Address (1). Enter the correct IP Address, e.g., 10.13.254.27, as
provided by appropriate engineering personnel.
3. Also from the System Management Configuration screen, enter the
correct Gateway and Subnet Mask addresses.
Once the IP Address info has been entered into the system, the final step in
the process involves assigning a Target ID (TID) to the system. Once
again, this information should be furnished by the appropriate engineering
personnel. An example of a TID is HSTNTXCA01012308S1, where the
first 8 characters are the Office CLLI, followed by an 8-character relay
rack location and a 2-character shelf id. The entire TID is limited to no
more than 20-characters.
The following procedures describe the process of inventorying the TID.
1. From the Main Menu, select Configuration (3), followed by System
Management (3).
2. From the System Management Configuration screen, select Circuit
Identification (16).
3. From the Equipment Identification screen, select Unit ID (1).
4. Enter the TID exactly as documented.
Assuming the proper Data Communications Network routing translations
have been performed by DCN administration personnel, attempt remote
access via Telnet Session to the shelf from a secure terminal or server
(DCN personnel should be able to do this). Work with DCN personnel as
necessary to troubleshoot problems.
Once the Ethernet connectivity is established to the shelf, NMA personnel
may also be contacted to confirm NMA accessibility for autonomous
alarming and/or remote provisioning/maintenance.
With Ethernet connectivity, remote personnel will also have access to the
user-friendly craft interface screens. Those screens, the same ones
available via the local craft port, will provide access to all OAM&P
(Operations, Administration, Maintenance and Provisioning) functions.
For those situations where X.25 is the transport medium for providing
remote access to the shelf, the Controllers have a built-in PAD and require