Seitenansicht 77
Chapter 4. Status
4-4 MX2810 M13 User Manual 61185001L1-1
POWER SUPPLY STATE
This field indicates which types of power supplies are installed (AC
or DC) in Card A and Card B and gives their current state:
Condition Description
DS3 Eqpt Fail
(SA)
The far-end unit or network is reporting a service-
affecting DS3 equipment failure.
DS3 Eqpt Fail
(NSA)
The far-end unit or network is reporting a non-
service-affecting DS3 equipment failure.
Common Eqpt
Fail (NSA)
The far-end unit or network is reporting a non-
service-affecting common equipment failure.
Multiple DS1
LOS
The far-end unit is experiencing a loss of signal on
multiple DS1s.
Single DS1
LOS
The far-end unit is experiencing a loss of signal on
a single DS1.
DS1 Eqpt Fail
(SA)
The far-end unit is experiencing a service-
affecting DS1 equipment failure.
DS1 Eqpt Fail
(NSA)
The far-end unit is experiencing a non-service-
affecting DS1 equipment failure.
Unknown The unit is unable to discern the status of the far-
end unit. (Normal for M13 framing.)
Condition Description
Normal The power supply is fully operational.
Error The controller card cannot communicate with the
power supply.
Power Low The power supply’s output level is abnormally low.
Power Fail The power supply’s input power is lost.
Temp High The power supply card temperature is abnormally
high.
Temp Critical The power supply card temperature is so high that
it will soon shut off completely.