Chapter 2. Installation and Operation
61185001L1-1 MX2810 M13 User Manual 2-13
Craft Port
The
CRAFT
port provides connection to a VT100 EIA-232
compatible interface.
Establishing Terminal Connection
To connect the MX2810 to a VT100 terminal, follow this procedure:
1. Configure the VT100 terminal for 9600, 19200, 38400, or 57600
baud, 8-bit characters, no parity, and one stop bit (xxxx, 8N1).
2. Connect the DTE port of a terminal to the DB-9 jack labeled
CRAFT
on the MX2810 front panel.
3. Initialize the terminal session.
4. Press
Enter
repeatedly until the password prompt appears.
5. Enter the username and password. The factory default
username is “
username
”. The factory default password is
“
password
”. The M
AIN
menu appears. See Figure 2-5.
6. Make selections by entering the number corresponding to the
chosen parameter. Press
ESC
on the keyboard to return to the
previous screen. End a terminal session by selecting L
OGOUT
from the M
AIN
menu or by pressing
Ctrl-C
at any time.
Only one menu session, through either Telnet or craft port, may be active
at a time. When an attempt to activate a second menu session is made,
the user will be asked if they want to disconnect the other menu session.
If “Yes” is chosen, the user (who must have “Admin” privileges) will be
required to enter a valid username and password. The new menu session
will be active at this time. The disconnected user will be notified and
provided with the username of the new user.