Chapter 3. Configuration
3-18 MX2810 M13 User Manual 61185001L1-1
DS3 Alarm Traps (Near-End Active and Standby Cards)
Trap If enabled, the unit issues a trap when...
LOS the controller card has lost the network Rx
signal
OOF the controller card detects a framing loss from
the network
AIS the controller card is receiving an AIS (blue)
alarm condition from the network. AIS alarms
occur when consecutive 1010s are received in
the information bits. This indicates that there is
a transmission fault located either at or
upstream from the transmitting terminal
RAI the controller card is receiving an RAI (yellow)
alarm from the network. This alarm is a signal
sent back toward the source of a failed transmit
circuit. The X-bits (X1 and X2) are set to zero
IDLE the controller card detects an idle sequence
from the network.
TX LOS the controller card’s transmitter has failed
XCV The controller card is receiving excessive code
violations, exceeding the threshold set by the
user (see XCV Threshold on page 3-11)
In/Out Test the DS3 is going in and out of test (applies to the
Active controller card only)