T1/E1 Alarms
Power Supply Alarms
T1/E1 alarms are cleared when the T1/E1 is disabled or set to A
UTO
E
NABLE
after receiving an alarm.
Alarm Description
LOS (Major) The unit has lost the receive signal on a
T1/E1.
Alarm Description
Malfunction
(Minor)
Power supply card is no longer working. The
unit has switched to the backup power supply or
battery backup.
Power Low
(Minor)
Power supply’s output level is abnormally low.
Power Fail
(Minor)
Power supply card does not detect power input.
Temperature
High (Minor)
Power supply card temperature is above
normal.
Temperature
Critical (Minor)
Power supply card temperature is so high that it
may suffer damage.
Input Fail
(Minor)
A power feed input (A or B) has failed.
Power Card
Removed
(Minor)
The unit detects that a Power Supply Card has
been removed.
If only using one power feed input, jumper the power feed to the unused
set of power feed terminals to prevent an Input Fail alarm.