Chapter 3. Configuration
61185001L1-1 MX2810 M13 User Manual 3-3
NETWORK INTERFACE
Select N
ETWORK
I
NTERFACE
to access the network configuration
parameters (see Figure 3-3). Configure the MX2810 network
settings to match the DS3 signal received from the service provider.
Figure 3-3. Network Configuration Menu
DS3 Configuration
Use the DS3 C
ONFIGURATION
selections to configure the DS3
network settings to match your application. Descriptions of these
settings follow:
Framing
Set the framing format to match the format of the receive signal at
the network interface. The MX2810 supports C-
BIT
and M13
framing formats.
Line Length
Set the line length to reflect the physical length of the DS3 network
line. Set to L
ONG
if the cabling distance exceeds 225 feet; set to
S
HORT
if the distance is less than 225 feet.
Timing
In most cases, configure the MX2810 for L
OOP
timing to derive
timing from the network. However, set to L
OCAL
if the MX2810 is
the master timing source for the circuit.