Global Configuration Mode Command Set Command Reference Guide
164 © 2003 ADTRAN, Inc. 61950860L1-35D
interface <port-type> <slot/port>
Activates the Interface Configuration Mode for the listed physical interface.
Syntax Description
<port-type>
Identifies the physical port type of the installed Network Interface Module (NIM)
Dial-Backup Interface Module (DIM) or Ethernet port. Type
interface ?
for a
complete list of valid interfaces.
<slot/port>
Specifies an interface based on its physical location (slot and port). For example,
if you have a T1/DSX-1 NIM installed in Slot 1 of an AOS product:
• The WAN-T1 port would be specified in the CLI as t1 1/1.
• The DSX-1 port would be specified as t1 1/2.
• If (for example) a BRI DIM is also installed, then the DBU port of the NIM
card would be specified as bri 1/3.
If you are specifying a port that is built into the base unit (e.g., the Ethernet port),
the slot number is
0
. For example, the Ethernet (
LAN
) port would be specified as
ethernet 0/1
.
Default Values
No default values required for this command.
Command Modes
(config)# Global Configuration Mode required
Command History
Release 1.1 Command was introduced
Usage Examples
The following example enters the serial interface command set for a serial module installed in slot 1:
(config)#
interface serial 1/1