DSX-1 Interface Configuration Command Set Command Reference Guide
352 © 2003 ADTRAN, Inc. 61950860L1-35D
line-length <value>
Use the line-length command to set the line build out (in feet or dB) for the DSX-1 interface. Use the no
form of this command to return to the default value.
Syntax Description
<value>
Configures the line build out for the DSX-1 interface
Valid options include: -7.5 dB or <0 to 655> feet
Default Values
<value>
0 feet
Command Modes
(config-t1 1/2)# DSX-1 Interface Configuration Mode required
Command History
Release 1.1 Command was introduced
Functional Notes
The
line-length
value represents the physical distance between DSX equipment (measured in cable length).
Based on this setting, the AOS device increases signal strength to compensate for the distance the signal must
travel.
Valid distance ranges are listed below:
• 0-133 feet
• 134-265 feet
• 266-399 feet
• 400-533 feet
• 534-655 feet
Usage Examples
The following example configures the DSX-1 interface
line-length
for 300 feet:
(config)#
interface t1 1/2
(config-t1 1/2)#
line-length 300
Kommentare zu diesen Handbüchern