Command Reference Guide T1 Interface Configuration Command Set
61950860L1-35D © 2003 ADTRAN, Inc. 335
clock source <option>
Use the clock source command to configure the source timing used for the interface. The clock specified
using the clock source command is also the system master clock. Use the no form of this command to
return to the default value.
M
Syntax Description
<option>
Configures the timing source for the T1 interface.
internal
Configures the unit to provide clocking using the internal oscillator.
line
Configures the unit to recover clocking from the primary circuit.
through
Configures the unit to recover clocking from the circuit connected to the DSX-1
interface.
Default Values
<option> line
Command Modes
(config-t1 1/1)# T1 or DSX-1 Interface Configuration Mode required.
(config-t1 1/2)#
Command History
Release 1.1 Command was introduced.
Functional Notes
When operating on a circuit that is providing timing, setting the
clock source
to
line
can avoid errors such as
Clock Slip Seconds (CSS).
Usage Examples
The following example configures the unit to recover clocking from the circuit:
(config)#
interface t1 1/1
(config-t1 1/1)#
clock source line